250kW Rack Emulator for AI Server Cooling | Eaton Boyd Thermal Data Center Solution
4:32
Revolutionize your AI data center commissioning with Eaton Boyd Thermal 250 kW Rack Emulator. This next-generation liquid cooling test solution precisely replicates the thermal and electrical behavior of AI server racks. The Rack emulator verifies the data center 's complete thermal system performance from simulated chip to CDU and facility chillers and cooling towers. Additionally, the Rack emulator validates electrical input power wiring and most importantly, simulates the server racks pressure drop to ensure cooling performance and dynamic real-world AI server operation. Key Features: • 250 kW thermal load with precise flow and pressure control • Simulates AI server rack pressure drop (6–40 psi / 0.4–2.75 bar) • Remote and local operation via 15.6-inch touchscreen and Modbus TCP/IP Ethernet • ASME-certified heater, UL-rated elements, dual disconnect switches for safety • Fluid connections support overhead and underfloor installations, fit for global data center standards Compact and mobile design with forklift-ready base Learn more about the Rack Emulator: www.boydcorp.com/rack-emulator.html Contact your Eaton Boyd Thermal Representative: www.boydcorp.com/contact-us.html
Revolutionize your AI data center commissioning with Eaton Boyd Thermal 250 kW Rack Emulator. This next-generation liquid cooling test solution precisely replicates the thermal and electrical behavior of AI server racks. The Rack emulator verifies the data center 's complete thermal system performance from simulated chip to CDU and facility chillers and cooling towers. Additionally, the Rack emulator validates electrical input power wiring and most importantly, simulates the server racks pressure drop to ensure cooling performance and dynamic real-world AI server operation. Key Features: • 250 kW thermal load with precise flow and pressure control • Simulates AI server rack pressure drop (6–40 psi / 0.4–2.75 bar) • Remote and local operation via 15.6-inch touchscreen and Modbus TCP/IP Ethernet • ASME-certified heater, UL-rated elements, dual disconnect switches for safety • Fluid connections support overhead and underfloor installations, fit for global data center standards Compact and mobile design with forklift-ready base Learn more about the Rack Emulator: www.boydcorp.com/rack-emulator.html Contact your Eaton Boyd Thermal Representative: www.boydcorp.com/contact-us.html
Eaton boyd thermal Similar Videos
-
How to Cool a Data Center with an In-rack Liquid Cooling System?
1:28
Eaton B offers forward-thinking, scalable Integrated Solutions for every aspect of Hyperscale Infrastructure & 5G -customized or configurable options that take facility-level cooled air & liquid down to board or chip systems through rack-level CDU’s.
-
What is a Thermosiphon?
1:22
Thermosiphons offer more cost-efficient two phase cooling than heat pipes or vapor chambers, but as they are wickless, they need a consistent gravitational pull to operate.
-
What is a 3D Direct Contact Loop Thermosiphon?
0:45
Thermosiphons that dissipate heat directly from a heat source in the adjacent volume are considered 3D Direct Contact Loop Thermosiphons.